22DILEM – Auxiliary contact module, 4 pole, 2 N/O, 2 NC, Front fixing, Screw terminals, DILE(E)M
DELIVERY PROGRAM
Accessories
Auxiliary contact modules
Description
with interlocked opposing contacts
Switching elements according to EN 50012
Switching elements according to EN 50012 are to be preferred.
Version E combinations correspond to EN 50011 and are to be preferred.
Function
for standard applications
Number of poles
4 pole
Connection technique
Screw terminals
Rated operational current
AC-15
220 V 230 V 240 V [Ie]
4 A
AC-15
380 V 400 V 415 V [Ie]
2 A
Contacts
N/O = Normally open
2 N/O
N/C = Normally closed
2 NC
Mounting type
Front fixing
For use with
DILEM-10(-G)(…)
DILEM-4(-G)(…)
DILEEM-10(-G)(…)
DILEM12-10(-G)(…)
Instructions
Interlocked opposing contacts according to IEC/EN 60947-5-1 appendix L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILER, DILE(E)M
Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open)
TECHNICAL DATA
General
Standards
IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
AC operated [Operations]
10 x 106
Lifespan, mechanical
DC operated [Operations]
20 x 106
Component lifespan at Ue = 240 V
AC-15 [Operations]
0.2 x 106
Component lifespan at Ue = 240 V
DC
L/R = 50 ms: 2 contacts in series at Ie = 0.5 A [Operations]
0.15 x 106
Maximum operating frequency [Operations/h]
9000
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
-25 – +50 °C
Ambient temperature
Enclosed
– 25 – 40 °C
Ambient temperature
Ambient temperature, storage
– 40 – 80 °C
Mounting position
Mounting position
As required, except vertical with terminals A1/A2 at the bottom
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Basic unit with auxiliary contact module
N/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27)
Half-sinusoidal shock, 10 ms
Basic unit with auxiliary contact module
N/C contact
8 g
Degree of Protection
IP20
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Weight
0.04 kg
Terminal capacities
Screw terminals
Solid
1 x (0.75 – 2.5)
2 x (0.75 – 2.5) mm2
Terminal capacities
Screw terminals
Flexible with ferrule
1 x (0.75 – 1.5)
2 x (0.75 – 1.5) mm2
Terminal capacities
Screw terminals
Solid or stranded
Single 18 – 14/Double 18 – 14 AWG
Terminal capacities
Screw terminals
Terminal screw
M3.5
Terminal capacities
Screw terminals
Pozidriv screwdriver
2 Size
Terminal capacities
Screw terminals
Standard screwdriver
0.8 x 5.5
1 x 6 mm
Terminal capacities
Screw terminals
Max. tightening torque
1.2 Nm
Contacts
Interlocked opposing contacts within an auxiliary contact module (to IEC 60947-5-1 Annex L)
Yes
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
600 V AC
Safe isolation to EN 61140
between coil and auxiliary contacts
300 V AC
Safe isolation to EN 61140
between the auxiliary contacts
300 V AC
Rated operational current
Conventional free air thermal current, 1 pole
Notes
At maximum permissible ambient air temperature.
Rated operational current
Conventional free air thermal current, 1 pole
Conv. thermal current [Ith]
10 A
Rated operational current
AC-15
220 V 230 V 240 V [Ie]
4 A
Rated operational current
AC-15
380 V 400 V 415 V [Ie]
2 A
Rated operational current
AC-15
500 V [Ie]
1.5 A
Rated operational current
DC current
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
1 [24 V]
2.5 A
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
2 [60 V]
2.5 A
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
3 [110 V]
1.5 A
Rated operational current
DC current
DC L/R ≦ 15 ms
Contacts in series:
3 [220 V]
0.5 A
Rated operational current
Control circuit reliability [Failure rate]
<10-8, < one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ Short-circuit rating without welding Maximum overcurrent protective device 220 V 230 V 240 V 4 PKZM0 Short-circuit rating without welding Maximum overcurrent protective device 380 V 400 V 415 V 4 PKZM0 Short-circuit rating without welding Short-circuit protection maximum fuse 500 V 6 A gG/gL Short-circuit rating without welding Short-circuit protection maximum fuse 500 V 10 A fast Current heat loss at Ith AC operated 1.5 W Current heat loss at Ith DC operated 1.5 W Current heat loss at Ith Current heat loss per auxiliary circuit at Ie (AC-15/230 V) 0.24 CO Rating data for approved types Auxiliary contacts Pilot Duty AC operated A600 Auxiliary contacts Pilot Duty DC operated P300 Auxiliary contacts General Use AC 600 V Auxiliary contacts General Use AC 10 A Auxiliary contacts General Use DC 250 V Auxiliary contacts General Use DC 0.5 A DESIGN VERIFICATION AS PER IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation [In] 4 A Heat dissipation per pole, current-dependent [Pvid] 0.24 W Equipment heat dissipation, current-dependent [Pvid] 0 W Static heat dissipation, non-current-dependent [Pvs] 0 W Heat dissipation capacity [Pdiss] 0 W Operating ambient temperature min. -25 °C Operating ambient temperature max. +50 °C IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2 Strength of materials and parts 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2 Strength of materials and parts 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9 Insulation properties 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9 Insulation properties 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TECHNICAL DATA ETIM 8.0 Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041) Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss10.0.1-27-37-13-02 [AKN342013]) Number of contacts as change-over contact 0 Number of contacts as normally open contact 2 Number of contacts as normally closed contact 2 Number of fault-signal switches 0 Rated operation current Ie at AC-15, 230 V 4 A Type of electric connection Screw connection Model Top mounting Mounting method Front fastening Lamp holder None APPROVALS Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No

From: 109,00  IVA esc.

Disponibilità: