DILM9-10 - EATON

DILM9-10 (24VDC) – Power contactor, 3p + 1NO, 4kW / 400V / AC3
276705
SUPPLY PROGRAM
Assortment
Power contactors
Application
Power contactor for motors
Below range
Power contactors up to 170 A, 3 poles
Use category
AC-1: Non-inductive or weakly inductive load, resistance furnaces
AC-3 / AC-3e: squirrel-cage motors: starting, stopping during operation
AC-4: Squirrel-cage motors: starting, electric counter-current brakes, reversing, movements impulse
Note
Can also be used for IE3 efficiency class motors.
Types of connection
Screw terminals
Poly
3-pole
Rated operational current
AC-3
Note
At maximum allowable ambient temperature (open)
Also tested in accordance with AC-3e.
AC-3
380 V 400 V [I e ]
9 A
AC-1
conventional free air thermal current, 3 poles, 50 – 60 Hz
per day
at 40 ° C [I th =I and ]
22 A
AC-1
conventional free air thermal current, 3 poles, 50 – 60 Hz
in custody [I th ]
18 A
AC-1
Conventional thermal current 1 pole
per day [I th ]
50 A
AC-1
Conventional thermal current 1 pole
in custody [I th ]
45 A
Max. Rated power of use for three-phase motors 50 – 60 Hz
AC-3
220V 230V [P]
2.5 kW
AC-3
380 V 400 V [P]
4 kW
AC-3
660 V 690 V [P]
4.5 kW
AC-4
220V 230V [P]
1.5 kW
AC-4
380 V 400 V [P]
2.5 kW
AC-4
660 V 690 V [P]
3.6 kW
Contact equipment
NA = norm. open
1 NO contact
Combinable with auxiliary contact
DILM32-XHI …
DILA-XHI (V) …
Control voltage
24 V DC
Type of current AC / DC
Direct current control
Connection to SmartWire-DT
yes
together with the DT DIL-SWD SmartWire contactor module
Note
Contact devices according to EN 50012.
Integrated varistor protection circuit
Size
1
TECHNICAL DATA
Generality
Compliance with standards
IEC / EN 60947, VDE 0660, UL, CSA
Durability, mechanics
Direct current command [Operations]
10 x 10 6
Operating frequency, mechanics
controlled in DC [Man / h]
9000
Suitability for climates
Humid heat, constant, according to IEC 60068-2-78
Humid heat, cyclic according to IEC 60068-2-30
Room temperature
per day
-25 – +60 ° C
Room temperature
in custody
– 25 – 40 ° C
Room temperature
Storage
-40 – 80 ° C
Shock resistance (IEC / EN 60068-2-27)
Sinusoidal shock 10 ms
Main contacts
NA contacts
10 g
Shock resistance (IEC / EN 60068-2-27)
Sinusoidal shock 10 ms
Auxiliary contacts
NA contacts
7 g
Shock resistance (IEC / EN 60068-2-27)
Sinusoidal shock 10 ms
Auxiliary contacts
NC contacts
5 g
Shock resistance (IEC / EN 60068-2-27) in table mounting
Sinusoidal shock 10 ms
Main contacts
NO contact
5.7 g
Shock resistance (IEC / EN 60068-2-27) in table mounting
Sinusoidal shock 10 ms
Auxiliary contacts
NO contact
3.4 g
Shock resistance (IEC / EN 60068-2-27) in table mounting
Sinusoidal shock 10 ms
Auxiliary contacts
NC contact
3.4 g
Degree of protection
IP20
Protection against accidental contact in case of frontal actuation (EN 50274)
Protection against finger and back of hand contact
Altitude
max. 2000 mm
Weight
controlled in DC
0.296 kg
Screw connection type
Main conductor connection cross sections
Stiff
1 x (0.75 – 4)
2 x (0.75 – 2.5) mm 2
Screw connection type
Main conductor connection cross sections
Flexible with ferrule
1 x (0.75 – 2.5)
2 x (0.75 – 2.5) mm 2
Screw connection type
Main conductor connection cross sections
Single wire or stranded
single 18 – 10, double 18 – 14 AWG
Screw connection type
Main conductor connection cross sections
Stripping length
10 mm
Screw connection type
Main conductor connection cross sections
Connecting screw
M3.5
Screw connection type
Main conductor connection cross sections
Starting time
1.2 Nm
Screw connection type
Main conductor connection cross sections
Tool
Pozidriv screwdriver
2 Size
Screw connection type
Main conductor connection cross sections
Tool
Flat-blade screwdriver
0.8 x 5.5
1 x 6 mm
Screw connection type
Auxiliary conductors connection cross sections
Stiff
1 x (0.75 – 4)
2 x (0.75 – 2.5) mm 2
Screw connection type
Auxiliary conductors connection cross sections
Flexible with ferrule
1 x (0.75 – 2.5)
2 x (0.75 – 2.5) mm 2
Screw connection type
Auxiliary conductors connection cross sections
Rigid or semi-rigid
18 – 14 AWG
Screw connection type
Auxiliary conductors connection cross sections
Stripping length
10 mm
Screw connection type
Auxiliary conductors connection cross sections
Connecting screw
M3.5
Screw connection type
Auxiliary conductors connection cross sections
Starting time
1.2 Nm
Screw connection type
Auxiliary conductors connection cross sections
Tool
Pozidriv screwdriver
2 Size
Screw connection type
Auxiliary conductors connection cross sections
Tool
Flat-blade screwdriver
0.8 x 5.5
1 x 6 mm
Main circuit
Rated impulse withstand voltage [U imp ]
8000 V AC
Overvoltage category / pollution degree
III / 3
Rated insulation voltage [U i ]
690 V AC
Rated operational voltage [U e ]
690 V AC
Safe isolation according to EN 61140
between coil and contacts
400 V AC
Safe isolation according to EN 61140
between contacts
400 V AC
Making capacity (cos ϕ according to IEC / EN 60947) [up to 690 V]
126 A
Opening power
220V 230V
90 A
Opening power
380 V 400 V
90 A
Opening power
500 V
70 A
Opening power
660 V 690 V
50 A
Short circuit resistance
Short circuit protection fuse max
Type of assignment “2”
400 V [gG / gL 500 V]
20 A
Short circuit resistance
Short circuit protection fuse max
Type of assignment “2”
690 V [gG / gL 690 V]
16 A
Short circuit resistance
Short circuit protection fuse max
Type of assignment “1”
400 V [gG / gL 500 V]
35 A
Short circuit resistance
Short circuit protection fuse max
Type of assignment “1”
690 V [gG / gL 690 V]
20 A
Alternating voltage
AC-1
Rated operational current
conventional free air thermal current, 3 poles, 50 – 60 Hz
per day
at 40 ° C [I th =I and ]
22 A
AC-1
Rated operational current
conventional free air thermal current, 3 poles, 50 – 60 Hz
per day
at 50 ° C [I th =I and ]
21 A
AC-1
Rated operational current
conventional free air thermal current, 3 poles, 50 – 60 Hz
per day
at 55 ° C [I th =I and ]
21 A
AC-1
Rated operational current
conventional free air thermal current, 3 poles, 50 – 60 Hz
per day
at 60 ° C [I th =I and ]
20 A
AC-1
Rated operational current
conventional free air thermal current, 3 poles, 50 – 60 Hz
in custody [I th ]
18 A
AC-1
Rated operational current
Conventional thermal current 1 pole
per day [I th ]
50 A
AC-1
Rated operational current
Conventional thermal current 1 pole
in custody [I th ]
45 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
Note
At maximum allowable ambient temperature (open)
Also tested in accordance with AC-3e.
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
220V 230V [I e ]
9 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
240 V [I e ]
9 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
380 V 400 V [I e ]
9 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
415 V [I e ]
9 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
440 V [I e ]
9 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
500 V [I e ]
7 A
AC-3
Rated operational current
open, 3 poles, 50 – 60 Hz
660 V 690 V [I e ]
5 A
AC-3
Rated absorbed power [P]
220 V 230 V [P]
2.5 kW
AC-3
Rated absorbed power [P]
240 V [P]
3 kW
AC-3
Rated absorbed power [P]
380 V 400 V [P]
4 kW
AC-3
Rated absorbed power [P]
415 V [P]
5.5 kW
AC-3
Rated absorbed power [P]
440 V [P]
5.5 kW
AC-3
Rated absorbed power [P]
500 V [P]
4.5 kW
AC-3
Rated absorbed power [P]
660 V 690 V [P]
4.5 kW
AC-4
open, 3 poles, 50 – 60 Hz
220V 230V [I e ]
6 A
AC-4
open, 3 poles, 50 – 60 Hz
240 V [I e ]
6 A
AC-4
open, 3 poles, 50 – 60 Hz
380 V 400 V [I e ]
6 A
AC-4
open, 3 poles, 50 – 60 Hz
415 V [I e ]
6 A
AC-4
open, 3 poles, 50 – 60 Hz
440 V [I e ]
6 A
AC-4
open, 3 poles, 50 – 60 Hz
500 V [I e ]
5 A
AC-4
open, 3 poles, 50 – 60 Hz
660 V 690 V [I e ]
4.5 A
AC-4
Rated absorbed power [P]
220V 230V [P]
1.5 kW
AC-4
Rated absorbed power [P]
240 V [P]
1.6 kW
AC-4
Rated absorbed power [P]
380 V 400 V [P]
2.5 kW
AC-4
Rated absorbed power [P]
415 V [P]
2.8 kW
AC-4
Rated absorbed power [P]
440 V [P]
3 kW
AC-4
Rated absorbed power [P]
500 V [P]
2.8 kW
AC-4
Rated absorbed power [P]
660 V 690 V [P]
3.6 kW
Continuous voltage
of three-phase open capacitors
DC-1
60 V [I e ]
20 A
of three-phase open capacitors
DC-1
110 V [I e ]
20 A
of three-phase open capacitors
DC-1
220 V [I e ]
15 A
Thermal dissipation (3 poles)
3 pole, with I th (60 °)
4.4 W
Thermal dissipation with I and according to AC-3/400 V
0.9 W
Impedance per pole
4.6 mΩ
Electromagnetic system
Voltage safety
Command in DC [Insertion]
0.8 – 1.1 x U c
Voltage safety
Note
0.85 – 1.1 only with auxiliary contact modules with 3 or more NC contacts
0.7 – 1.3 without auxiliary contact module and with an ambient temperature of +40 ° C
Voltage safety
Dropout voltage with DC command [Disconnect]
0.15 – 0.6 x U c
Voltage safety
Note
two half-wave rectifier bridge leveled at minimum or AC rectifier
Absorbed power of the coil when cold and with 1.0 x U S
Direct current control [Insertion]
4.5 W
Absorbed power of the coil when cold and with 1.0 x U S
DC control [Hold]
4.5 W
Duration of insertion
100% on duration
Operating times at 100% U C (indicative values)
Main contacts
controlled in DC
Closing time
Closing time
<31 ms Operating times at 100% U C (indicative values) Main contacts controlled in DC Opening time Opening time <12 ms Operating times at 100% U C (indicative values) Duration of the arc 10 ms Electromagnetic Compatibility (EMC) Interference emitted according to EN 60947-1 Noise immunity according to EN 60947-1 Power data approved Breaking power Maximum engine power three-phase 200V 208V 3 HP Breaking power Maximum engine power three-phase 230 V 240 V 3 HP Breaking power Maximum engine power three-phase 460V 480V 5 HP Breaking power Maximum engine power three-phase 575V 600V 7.5 HP Breaking power Maximum engine power single phase 115V 120V 0.5 HP Breaking power Maximum engine power single phase 230 V 240 V 1.5 HP Breaking power General use 20 A Auxiliary contacts Pilot Duty Control in alternating current A600 Auxiliary contacts Pilot Duty Direct current control P300 Auxiliary contacts General Use B.C 600 V Auxiliary contacts General Use B.C 10 A Auxiliary contacts General Use A.D 250 V Auxiliary contacts General Use A.D 1 A Short Circuit Current Rating Basic Rating SCCR 5 kA Short Circuit Current Rating Basic Rating max. Fuse 45 A Short Circuit Current Rating Basic Rating max. CB 60 A Short Circuit Current Rating 480 V High Fault SCCR (Fuse) 30/100 kA Short Circuit Current Rating 480 V High Fault max. Fuse 25 Class RK5 / 20 Class JA Short Circuit Current Rating 480 V High Fault SCCR (CB) 65 kA Short Circuit Current Rating 480 V High Fault max. CB 16 A Short Circuit Current Rating 600 V High Fault SCCR (Fuse) 30/100 kA Short Circuit Current Rating 600 V High Fault max. Fuse 25 Class RK5 / 20 Class JA Special Purpose Ratings Electrical Discharge Lamps (Ballast) 480V 60Hz three phase, 277V 60Hz single phase 18 A Special Purpose Ratings Electrical Discharge Lamps (Ballast) 600V 60Hz three-phase, 347V 60Hz single-phase 18 A Special Purpose Ratings Incandescent Lamps (Tungsten) 480V 60Hz three phase, 277V 60Hz single phase 14 A Special Purpose Ratings Incandescent Lamps (Tungsten) 600V 60Hz three-phase, 347V 60Hz single-phase 14 A Special Purpose Ratings Resistance Air Heating 480V 60Hz three phase, 277V 60Hz single phase 18 A Special Purpose Ratings Resistance Air Heating 600V 60Hz three-phase, 347V 60Hz single-phase 18 A Special Purpose Ratings Refrigeration Control (CSA only) LRA 480V 60Hz three-phase 60 A Special Purpose Ratings Refrigeration Control (CSA only) FLA 480V 60Hz three-phase 10 A Special Purpose Ratings Refrigeration Control (CSA only) LRA 600V 60Hz three-phase 60 A Special Purpose Ratings Refrigeration Control (CSA only) FLA 600V 60Hz three-phase 10 A Special Purpose Ratings Definite Purpose Ratings (100,000 cycles acc. To UL 1995) LRA 480V 60Hz three-phase 54 A Special Purpose Ratings Definite Purpose Ratings (100,000 cycles acc. To UL 1995) FLA 480V 60Hz three-phase 9 A Special Purpose Ratings Elevator Control 200V 60Hz three-phase 2 HP Special Purpose Ratings Elevator Control 200V 60Hz three-phase 7.8 A Special Purpose Ratings Elevator Control 240V 60Hz three-phase 2 HP Special Purpose Ratings Elevator Control 240V 60Hz three-phase 6.8 A Special Purpose Ratings Elevator Control 480V 60Hz three phase 3 HP Special Purpose Ratings Elevator Control 480V 60Hz three phase 4.8 A Special Purpose Ratings Elevator Control 600V 60Hz three-phase 5 HP Special Purpose Ratings Elevator Control 600V 60Hz three-phase 6.1 A DESIGN VERIFICATIONS ACCORDING TO IEC / EN 61439 Technical data for design checks Rated operational current for dissipation data [I n ] 9 A Dissipation per pole, as a function of the current [P vid ] 0.3 W Device dissipation, depending on the current [P vid ] 0 W Static dissipation, independent of the current [P vs ] 4.5 W Dissipation power [P ve ] 0 W Ambient service temperature min. -25 ° C Ambient service temperature max. +60 ° C IEC / EN 61439 design verifications 10.2 Suitability of materials and components 10.2.2 Corrosion resistance The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.3.1 Resistance of the enclosure to heat The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.3.2 Resistance of insulating materials to normal heat levels The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.3.3 Resistance of insulating materials to extraordinary heat levels The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.4 Resistance to UV radiation The requirements of the product standard are met. 10.2 Suitability of materials and components 10.2.5 Lifting Not relevant as the whole electrical panel needs to be evaluated. 10.2 Suitability of materials and components 10.2.6 Impact test Not relevant as the whole electrical panel needs to be evaluated. 10.2 Suitability of materials and components 10.2.7 Lettering The requirements of the product standard are met. 10.3 Degree of protection of the enclosures Not relevant as the whole electrical panel needs to be evaluated. 10.4 Airborne and superficial dispersion routes The requirements of the product standard are met. 10.5 Protection against electric shock Not relevant as the whole electrical panel needs to be evaluated. 10.6 Flush mounting of devices Not relevant as the whole electrical panel needs to be evaluated. 10.7 Internal circuits and connections It is the responsibility of the manufacturer of the electrical panel. 10.8 Connections for conductors introduced from outside It is the responsibility of the manufacturer of the electrical panel. 10.9 Insulation characteristics 10.9.2 Dielectric strength at mains frequency It is the responsibility of the manufacturer of the electrical panel. 10.9 Insulation characteristics 10.9.3 Impulse withstand voltage It is the responsibility of the manufacturer of the electrical panel. 10.9 Insulation characteristics 10.9.4 Verification of enclosures in insulating material It is the responsibility of the manufacturer of the electrical panel. 10.10 Heating The superheat calculation is the responsibility of the electrical panel builder. Eaton provides equipment dissipation data. 10.11 Resistance to short circuit It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment. 10.12 EMC It is the responsibility of the manufacturer of the electrical panel. Observe the default values of the equipment. 10.13 Mechanical function For the device, the requirements are met if the information in the installation instructions (IL) is observed. TECHNICAL DATA ACCORDING TO ETIM 8.0 low voltage electrical appliances (EG000017) / AC changeover contact (EC000066) Technique Of Ar., Electr., Energy, Tecn. Switchgear, Network & Mains Process / Low Voltage Switching Technology / Contactor (Ns) / Power Contactor (ecl@ss10.0.1-27-37-10-03 [AAB718015]) nominal pilot supply voltage Us for AC 50 Hz 0 - 0 V nominal pilot supply voltage Us for AC 60 Hz 0 - 0 V nominal pilot supply voltage Us for DC 24 - 24 V type of voltage for the drive A.D rated operating current Ie for AC-1, 400 V 22 A rated operating current Ie for AC-3, 400 V 9 A rated operating power for AC-3, 400 V 4 kW rated operating current Ie for AC-4, 400 V 6 A rated operating power for AC-4, 400 V 2.5 kW NEMA rated operating power 3.7 kW suitable for series installation no number of auxiliary contacts, closing contacts 1 number of auxiliary contacts, rest contacts 0 type of main electrical circuit connection screw connection number of opening contacts, main contacts 0 number of closing contacts, main contacts 3 APPROVALS Product Standards IEC / EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking UL File No. E29096 UL Category Control No. NLDX CSA File No. 012528 CSA Class No. 2411-03, 3211-04 North America Certification UL listed, CSA certified Specially designed for North America No