P1-32/I2/SVB/N - MOELLER

Product range
Main switch
maintenance switch
Part group reference
P1
Stop Function
Emergency switching off function
With red rotary handle and yellow locking ring
Information about equipment supplied
auxiliary contact fitted by user.
Number of poles
3 pole + N
Auxiliary contacts
0 N/O
0 N/C
Locking facility
Lockable in the 0 (Off) position
Degree of Protection
IP65
Switching angle
90 °
Motor rating AC-23A, 50 – 60 Hz [P]
400 V [P]
15 kW
Rated uninterrupted current [Iu]
32 A
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
TECHNICAL DATA
General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Enclosed
-25 – +40 °C
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage [Uimp]
6000 V AC
Mechanical shock resistance
15 g
Mounting position
As required
Contacts
Mechanical variables
Number of poles
3 pole + N
Mechanical variables
Auxiliary contacts

0 N/O
Mechanical variables
Auxiliary contacts

0 N/C
Electrical characteristics
Rated operational voltage [Ue]
690 V AC
Electrical characteristics
Rated uninterrupted current [Iu]
32 A
Electrical characteristics
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
AB 25 % DF
2 x Ie
Load rating with intermittent operation, class 12
AB 40 % DF
1.6 x Ie
Load rating with intermittent operation, class 12
AB 60 % DF
1.3 x Ie
Short-circuit rating
Fuse
50 A gG/gL
Rated short-time withstand current (1 s current) [Icw ]
640 Arms
Note on rated short-time withstand current lcw
Current for a time of 1 second
Rated conditional short-circuit current [Iq]
80 kA
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
320 A
Rated breaking capacity cos ϕ to IEC 60947-3
230 V
260 A
Rated breaking capacity cos ϕ to IEC 60947-3
400/415 V
300 A
Rated breaking capacity cos ϕ to IEC 60947-3
500 V
290 A
Rated breaking capacity cos ϕ to IEC 60947-3
690 V
250 A
Safe isolation to EN 61140
between the contacts
440 V AC
Safe isolation to EN 61140
Current heat loss per contact at Ie
1.8 W
Lifespan, mechanical [Operations]
> 0.3 x 106
Maximum operating frequency [Operations/h]
1200
AC
AC-3
Rating, motor load switch [P]
220 V 230 V [P]
7.5 kW
AC
AC-3
Rating, motor load switch [P]
400 V 415 V [P]
13 kW
AC
AC-3
Rating, motor load switch [P]
500 V [P]
18.5 kW
AC
AC-3
Rating, motor load switch [P]
690 V [P]
15 kW
AC
AC-3
Rated operational current motor load switch
230 V [Ie]
26.4 A
AC
AC-3
Rated operational current motor load switch
400V 415 V [Ie]
26.4 A
AC
AC-3
Rated operational current motor load switch
500 V [Ie ]
23.4 A
AC
AC-3
Rated operational current motor load switch
690 V [Ie]
14.7 A
AC
AC-23A
Motor rating AC-23A, 50 – 60 Hz [P]
230 V [P]
7.5 kW
AC
AC-23A
Motor rating AC-23A, 50 – 60 Hz [P]
400 V 415 V [P]
15 kW
AC
AC-23A
Motor rating AC-23A, 50 – 60 Hz [P]
500 V [P]
18.5 kW
AC
AC-23A
Motor rating AC-23A, 50 – 60 Hz [P]
690 V [P]
15 kW
AC
AC-23A
Rated operational current motor load switch
230 V [Ie]
32 A
AC
AC-23A
Rated operational current motor load switch
400 V 415 V [Ie]
32 A
AC
AC-23A
Rated operational current motor load switch
500 V [Ie]
30 A
AC
AC-23A
Rated operational current motor load switch
690 V [Ie]
19.8 A
DC
DC-1, Load-break switches L/R = 1 ms
Rated operational current [Ie]
32 A
DC
DC-1, Load-break switches L/R = 1 ms
Voltage per contact pair in series
60 V
DC
DC-23A, motor load switch L/R = 15 ms
24 V
Rated operational current [Ie]
25 A
DC
DC-23A, motor load switch L/R = 15 ms
24 V
Contacts
1 Quantity
DC
DC-23A, motor load switch L/R = 15 ms
48 V
Rated operational current [Ie]
25 A
DC
DC-23A, motor load switch L/R = 15 ms
48 V
Contacts
2 Quantity
DC
DC-23A, motor load switch L/R = 15 ms
60 V
Rated operational current [Ie]
25 A
DC
DC-23A, motor load switch L/R = 15 ms
60 V
Contacts
2 Quantity
DC
DC-23A, motor load switch L/R = 15 ms
120 V
Rated operational current [Ie]
12 A
DC
DC-23A, motor load switch L/R = 15 ms
120 V
Contacts
3 Quantity
Control circuit reliability at 24 V DC, 10 mA [Fault probability]
< 10-5,< 1 failure in 100,000 switching operations HF Terminal capacities Solid or stranded 1 x (1,5 - 6) 2 x (1,5 - 6) mm2 Flexible with ferrules to DIN 46228 1 x (1 - 4) 2 x (1 - 4) mm2 Terminal screw M4 Tightening torque for terminal screw 1.6 Nm Technical safety parameters: Notes B10d values as per EN ISO 13849-1, table C1 Rating data for approved types Terminal capacity Terminal screw M4 Terminal capacity Tightening torque 14.128 lb-in