Duenne non è un rivenditore autorizzato

TM-2-8292-E-SVB - EATON

TM-2-8292/E/SVB 045484 EATON ELECTRIC
Control circuit switches, Emergency-Stop function, Contacts: 3, 10 A
Delivery program
Product range
Control switches
Part group reference
TM
Basic function
Control circuit switches
Stop Function
Emergency switching off function
With red rotary handle and yellow locking ring
Notes
up to 250 V AC per contact
Contacts
3
Locking facility
Lockable in the 0 (Off) position
Degree of Protection
Front IP65
Design
flush mounting
000Z427
Contact sequence
115S009-2
Switching angle
90 °
Design number
8292
Front plate no.
115N005
Motor rating AC-23A, 50 – 60 Hz [P]
400 V [P]
3 kW
Rated uninterrupted current [Iu]
10 A
Note on rated uninterrupted current !u
Rated uninterrupted current I
u
is specified for max. cross-section.
Number of contact units
2 contact unit(s)
Technical data
General
Standards
IEC/EN 60947, VDE 0660, CSA, UL
Control switch as per IEC/EN 60947-5-1
Auxiliary switch as per IEC/EN 60947-5-1
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
-25 – +50 °C
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage [Uimp]
4000 V AC
Mounting position
As required
Contacts
Electrical characteristics
Rated operational voltage [Ue]
500 V AC
Electrical characteristics
Rated uninterrupted current [Iu]
10 A
Electrical characteristics
Note on rated uninterrupted current !u
Rated uninterrupted current I
u
is specified for max. cross-section.
Short-circuit rating
Fuse
10 A gG/gL
Switching capacity
Safe isolation to EN 61140
Current heat loss per contact at Ie
0.15 W
Safe isolation to EN 61140
Current heat loss per auxiliary circuit at Ie(AC-15/230 V)
0.15 CO
Lifespan, mechanical [Operations]
> 1 x 10
6
Maximum operating frequency [Operations/h]
1200
AC
AC-23A
Motor rating AC-23A, 50 – 60 Hz [P]
400 V 415 V [P]
3 kW
Control circuit reliability at 24 V DC, 10 mA [Fault probability]
< 10 -5 ,< 1 failure in 100,000 switching operations H F Terminal capacities Solid or stranded 1 x 1,5 2 x 1,5 mm 2 Flexible with ferrules to DIN 46228 1 x 1.0 2 x 1.0 mm 2 Flexible 1 x 1.5 2 x 1.5 mm 2 Terminal screw M2.5 Tightening torque for terminal screw 0.4 Nm Rating data for approved types Contacts Rated operational voltage [Ue] 300 V AC Contacts Rated uninterrupted current max. Main conducting paths General use 10 A Contacts Rated uninterrupted current max. Auxiliary contacts General Use [IU] 10 A Contacts Rated uninterrupted current max. Auxiliary contacts Pilot Duty A 300 Switching capacity Maximum motor rating Single-phase 120 V AC 0.33 HP Switching capacity Maximum motor rating Single-phase 240 V AC 0.75 HP Switching capacity Maximum motor rating Single-phase 277 V AC 0.75 HP Switching capacity Maximum motor rating Three-phase 120 V AC 0.75 HP Switching capacity Maximum motor rating Three-phase 240 V AC 1 HP Terminal capacity Solid or flexible conductor with ferrule 14 AWG Terminal capacity Terminal screw M2.5 Terminal capacity Tightening torque 3.5 lb-in Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation [In] 10 A Heat dissipation per pole, current-dependent [Pvid] 0.15 W Equipment heat dissipation, current-dependent [Pvid] 0 W Static heat dissipation, non-current-dependent [Pvs] 0 W Heat dissipation capacity [Pdiss] 0 W Operating ambient temperature min. -25 °C Operating ambient temperature max. +50 °C IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2 Strength of materials and parts 10.2.4 Resistance to ultra-violet (UV) radiation UV resistance only in connection with protective shield. 10.2 Strength of materials and parts 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2 Strength of materials and parts 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2 Strength of materials and parts 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9 Insulation properties 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9 Insulation properties 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 7.0 Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector (ecl@ss10.0.1-27-37-14-03 [AKF060013]) Version as main switch Yes Version as maintenance-/service switch Yes Version as safety switch No Version as emergency stop installation Yes Version as reversing switch No Number of switches 1 Max. rated operation voltage Ue AC 500 V Rated operating voltage 500 - 500 V Rated permanent current Iu 10 A Rated permanent current at AC-23, 400 V A Rated permanent current at AC-21, 400 V 0 A Rated operation power at AC-3, 400 V 0 kW Rated short-time withstand current lcw 0 kA Rated operation power at AC-23, 400 V 0 kW Switching power at 400 V 0 kW Conditioned rated short-circuit current Iq 0 kA Number of poles 3 Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Motor drive optional No Motor drive integrated No Voltage release optional No Device construction Built-in device fixed built-in technique Suitable for ground mounting No Suitable for front mounting 4-hole Yes Suitable for front mounting centre No Suitable for distribution board installation No Suitable for intermediate mounting No Colour control element Red Type of control element Door coupling rotary drive Interlockable Yes Type of electrical connection of main circuit Screw connection Degree of protection (IP), front side IP65 Degree of protection (NEMA) Other Approvals Product Standards UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking UL File No. E36332 UL Category Control No. NLRV CSA File No. UL report applies to both US and Canada North America Certification UL listed, certified by UL for use in Canada Degree of Protection IEC: IP65; UL/CSA Type: –