Valve unit
VTUG
573606
Technical data
Electric control
AP interface Single link Fieldbus I-Port IO-Link® Multi-pole connector
I/O electrical system
no
Working fluid
Compressed air according to ISO 8573-1:2010 [7:4:4]
Pilot fluid
Compressed air according to ISO 8573-1:2010 [7:4:4]
Note on operating and control fluid
Possibility of lubricated operation (in this case a lubricated operation will always be required)
Fluid temperature
-5°C … 60°C
Room temperature
-5°C … 60°C
Storage temperature
-10°C … 60°C
Degree of protection
IP40 IP65 IP67 IP69K NEMA 4X
Corrosion resistance class CRC
2 – Moderate corrosion stress
Vibration resistance
Application test for transport with severity level 2 according to FN 942017-4 and EN 60068-2-6
Impact resistance
Impact test with severity level 2 according to FN 942017-5 and EN 60068-2-27
Operating pressure
-0.09MPa … 1MPa
Work pressure
-0.9bar … 10bar
Pilot pressure Mpa
0.15MPa … 0.8MPa
Pilot pressure
1.5bar … 8bar
Operating pressure for valve terminals with internal pilot air supply
1.5bar … 8bar
PWIS compliant
VDMA24364-B1/B2-L
CE mark (see declaration of conformity)
Complies with EMC Directive Complies with EU RoHS directive
CE mark (see declaration of conformity)
UK Instructions for EMC RoHS Instructions UK
KC brand
KC-EMV
Approval
Trademark RCM c UL us – Recognized (OL)
Authority issuing the certificate
UL MH19482
Note on materials
Compliant with EU Directive 2002/95 (RoHS)
Gasket material
HNBR NBR
Valve terminal design
Fixed wheelbase
Maximum number of valve positions
24
number max. of pressure zones
13
Drive type
Electric
Valve function
2×3/2-way, monostable, closed 2×3/2-way, open, monostable 2×3/2-way, open/closed, monostable 3/2-way, closed, monostable 3/2 open, single solenoid 5/2 double solenoid 5/2-way, monostable 5/3 ways, pressurized 5/3 unloaded 5/3 closed centres
Design
Piston shutter
Sealing principle
Soft
Type of piloting
Piloted
Valve size
14mm
Pilot air
External Internal
Standard nominal flow rate max.
330 l/min at 10 mm 630 l/min at 14 mm 1200 l/min at 18 mm
Standard nominal flow rate
130l/min … 1150l/min
Suitability for vacuum
Yes
Exhaust air function
With flow control option
pneumatic working door
M5 M7 G1/8 G1/4 QS-3 QS-4 QS-6 QS-8 QS-10 QS-5/32 QS-1/8 QS-3/16 QS-1/4 QS-5/16 QS- 3/8
Pneumatic connection, port 1
G1/8 G1/4 G3/8 QS-3 QS-4 QS-6 QS-8 QS-10 QS-12 QS-16 QS-1/4 QS-5/16 QS-3/8 QS-1/2
Servo pilot connection 12/14
G1/8
Signal status display
LEDs
Rated operational voltage DC
24th
Permitted fluctuations for the supply voltage
+/- 10% +/- 25%
Nominal absorption current for solenoid valve
47mA up to 20ms
Rated current with current reduction
15.5mA after 20ms
From: 789,00 € IVA esc.