DC / DC Converter – QUINT-PS / 24DC / 24DC / 20
2320102
QUINT DC / DC switching converter for rail mounting with SFB (Selective Fuse Breaking) technology, input: 24 V DC, output: 24 V DC / 20 A
QUINT POWER converters with maximum functionality
DC / DC converters convert the voltage level, increase the voltage on longer lines or provide independent power supply systems by means of galvanic isolation.
For the selective and consequently economic protection of the systems, the DC / DC QUINT Converters are able to trip magnetothermic switches with values equal to 6 times the rated current, in a magnetic and therefore rapid way. The high reliability of the plant is also guaranteed by the preventive functional check, which communicates critical operating states before errors occur.

DC operation
Input voltage range 24 V DC
Input voltage range 18 V DC … 32 V DC
Extended input voltage range in operation 14 V DC … 18 V DC (Derating)
Extended range input no
DC input voltage range 18 V DC … 32 V DC
14 V DC … 18 V DC (Observe derating during operation)
Inrush current pulse <26 A (typ.) Integral of peak inrush current (I 2 t) <11 A 2 s Network outage coverage time typ. 10 ms (24 V DC) Current consumption 28 A (24 V, I BOOST ) Reverse polarity protection ≤ yes 30 V DC Protection circuit Transient overvoltage protection; Varistor Selection of a suitable fuse for input protection 40 A ... 50 A (Characteristic B, C, D, K) Efficiency > 93%
Output feature U / I
Nominal output voltage 24 V DC ± 1%
Output voltage regulation (U Set ) 18 V DC … 29.5 V DC (> 24 V DC, limited constant power)
Rated output current (I N ) 20 A (-25 ° C … 60 ° C)
POWER BOOST (I Boost ) 25 A (-25 ° C … 40 ° C constant, U OUT = 24 V DC)
Selective Fuse Breaking (I SFB ) 120 A (12 ms)
Magnetic fuse protection B2 / B4 / B6 / B10 / B16 / C2 / C4 / C6
Derating 60 ° C … 70 ° C (2.5% / K)
Output overvoltage protection (OVP) <35 V DC Maximum capacitive load Unlimited Active current limitation ca. 29 A Adjustment deviation <1% (static load variation 10% ... 90%) <2% (dynamic load variation 10% ... 90%) <0.1% (input voltage variation ± 10%) Residual ripple <20 mV SS Power output 480 W Nominal load switching peaks <10 mV SS (20 MHz) Max. Power dissipated in no-load condition 2.2 W Max. Power dissipated with nominal load 39 W Response time <2 ms (U OUT (10% ... 90%)) Parallel connection yes, for redundancy and power increase Possibility of connection in series Yes Signal: DC OK, active Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof) Signal: POWER BOOST, active Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof) Signal: POWER BOOST, active Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof) Signal: POWER BOOST, active Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof) Signal: POWER BOOST, active Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Entrance
Connection Screw connection
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 16 mm²
Conductor cross section flexible min. 0.5 mm²
Conductor cross section flexible max. 16 mm²
Conductor cross section AWG min. 8
Conductor cross section AWG max. 6
Stripping length 10 mm
Thread M3
Min torque 1.2 Nm
Max torque 1.5 Nm
Exit
Connection Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 12
Conductor cross section AWG max. 10
Stripping length 8 mm
Thread M3
Min torque 0.5 Nm
Max torque 0.6 Nm
Signal
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Thread M3
Min torque 0.5 Nm
Max torque 0.6 Nm
Types of reporting LED
Switching output active
Relay contact
Signal output: DC OK, active
Status reporting Green “DC OK” LED
Note regarding the status indicator U OUT <0.9 x U N : LED flashing Color green Note regarding the status indicator Flashing LED Signal output: POWER BOOST, active Status reporting "BOOST" LED yellow / I OUT > I N : LED on
Color yellow
Note regarding the status indicator LED on
Signal output: U IN OK, active
Status reporting Yellow “U IN <19.2 V" LED / U IN <19.2 V DC: LED on Color yellow Note regarding the status indicator LED on Signal output: DC OK, potential free Note regarding the status indicator U OUT > 0.9 x U N : closed contact
Number of phases 1.00
Input / output insulation voltage 1.5 kV (approval)
1 kV (Testing)
Input / output insulation voltage 1 kV (approval)
Product type DC / DC Converter
MTBF (IEC 61709, SN 29500) > 554000 h (40 ° C)
Features of insulation
Protection class III
Degree of pollution 2
Length 82 mm
Height 130 mm
Depth 125 mm
Mounting dimensions
Left / right mounting distance 0 mm / 0 mm (≤ 70 ° C)
Left / right side installation distance (active) 15 mm / 15 mm (≤ 70 ° C)
Top / bottom mounting distance 50 mm / 50 mm (≤ 70 ° C)
Top / Bottom Mounting Distance (Active) 50 mm / 50 mm (≤ 70 ° C)
Alternative mounting
Length 122 mm
Height 130 mm
Depth 85 mm
Mounting type Rail mounting
Assembly instructions tileable: P N ≥50%, horizontally 5 mm, close to active components 15 mm, vertically 50 mm
tileable: P N <50%, horizontally 0 mm, vertical above 40 mm, vertical below 20 mm Installation position Horizontal support rail NS 35, EN 60715 With protective paint No Color aluminum Case material Metal Housing material Aluminum (AlMg3) Shell version Galvanized steel sheet, chromium (VI) free Environmental conditions Degree of protection IP20 Ambient temperature (operation) -25 ° C ... 70 ° C (> 60 ° C derating, 2.5% / K, start-up approved at -40 ° C)
Ambient temperature (storage / transport) -40 ° C … 85 ° C
Ambient temperature (Startup type tested) -40 ° C
Air conditioning class 3K3 (according to EN 60721)
Maximum permissible air humidity (operation) ≤ 95% (at 25 ° C, no condensation)
Bumps 18 ms, 30g in each direction (according to IEC 60068-2-27)
Vibrations (operation) <15 Hz, amplitude ± 2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min. Railway applications EN 50121-4 Regulatory reference - Electronic equipment for use in power installations EN 50178 / VDE 0160 (PELV) Electrical safety according to law EN 60950-1 / VDE 0805 (SELV) Normative reference - Low voltage protection EN 60950-1 (SELV) EN 60204 (PELV) Safe separation according to law DIN VDE 0100-410 Homologation for the naval sector DNV GL (EMC B) UL approvals UL / C-UL Listed UL 508 UL / C-UL Recognized UL 60950-1 UL ANSI / ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) Electromagnetic compatibility Compliance with the EMC directive 2014/30 / EU Electromagnetic Interference Requirements Noise emission EN 61000-6-3 EN 61000-6-4 Electromagnetic Interference Requirements Noise immunity EN 61000-6-1 EN 61000-6-2 Noise immunity EN 61000-6-2: 2005 Electrostatic discharges Standards / Provisions EN 61000-4-2 Electrostatic discharges Download contacts 8 kV (Test severity grade 4) Download in the air 15 kV (Test severity grade 4) Remarks Criterion A High frequency electromagnetic fields Standards / Provisions EN 61000-4-3 High frequency electromagnetic fields Frequency 80 MHz ... 1 GHz Strength of the test field 10 V / m Frequency 1 GHz ... 2 GHz Strength of the test field 10 V / m Frequency 2 GHz ... 3 GHz Strength of the test field 10 V / m Remarks Criterion A Fast transients (Burst) Standards / Provisions EN 61000-4-4 Fast transients (Burst) Entrance 2 kV (Test severity grade 3 - asymmetric) Exit 2 kV (Test severity grade 3 - asymmetric) Signal 2 kV (Test severity grade 4 - asymmetric) Remarks Criterion A Solicitation of voltage pulses (surge) Standards / Provisions EN 61000-4-5 Entrance 1 kV (Test severity grade 2 - symmetrical) 2 kV (Test severity grade 3 - asymmetric) Exit 1 kV (Test severity grade 2 - symmetrical) 2 kV (Test severity grade 3 - asymmetric) Signal 1 kV (Test severity grade 2 - asymmetric) Remarks Criterion A Influence conducted Standards / Provisions EN 61000-4-6 Influence conducted I / O / S asymmetrical Frequency 0.15 MHz ... 80 MHz Remarks Criterion A Voltage 10 V (Test severity grade 3) Noise emission Standards / Provisions EN 61000-6-3 Radio interference voltage according to EN 55011 standard EN 55011 (EN 55022) class B field of use Industry and domestic environment Radio interference range according to EN 55011 standard EN 55011 (EN 55022) class B field of use Industry and domestic environment Criterion A Normal status reporting within the set limits. Criterion B Status signal temporarily compromised, corrected automatically by the device.