Duenne non è un rivenditore autorizzato PHOENIX
2320102 – PHOENIX
DC / DC Converter – QUINT-PS / 24DC / 24DC / 20
2320102
QUINT DC / DC switching converter for rail mounting with SFB (Selective Fuse Breaking) technology, input: 24 V DC, output: 24 V DC / 20 A
QUINT POWER converters with maximum functionality
DC / DC converters convert the voltage level, increase the voltage on longer lines or provide independent power supply systems by means of galvanic isolation.
For the selective and consequently economic protection of the systems, the DC / DC QUINT Converters are able to trip magnetothermic switches with values equal to 6 times the rated current, in a magnetic and therefore rapid way. The high reliability of the plant is also guaranteed by the preventive functional check, which communicates critical operating states before errors occur.
DC operation
Input voltage range 24 V DC
Input voltage range 18 V DC … 32 V DC
Extended input voltage range in operation 14 V DC … 18 V DC (Derating)
Extended range input no
DC input voltage range 18 V DC … 32 V DC
14 V DC … 18 V DC (Observe derating during operation)
Inrush current pulse <26 A (typ.)
Integral of peak inrush current (I 2 t) <11 A 2 s
Network outage coverage time typ. 10 ms (24 V DC)
Current consumption 28 A (24 V, I BOOST )
Reverse polarity protection ≤ yes 30 V DC
Protection circuit Transient overvoltage protection; Varistor
Selection of a suitable fuse for input protection 40 A ... 50 A (Characteristic B, C, D, K)
Efficiency > 93%
Output feature U / I
Nominal output voltage 24 V DC ± 1%
Output voltage regulation (U Set ) 18 V DC … 29.5 V DC (> 24 V DC, limited constant power)
Rated output current (I N ) 20 A (-25 ° C … 60 ° C)
POWER BOOST (I Boost ) 25 A (-25 ° C … 40 ° C constant, U OUT = 24 V DC)
Selective Fuse Breaking (I SFB ) 120 A (12 ms)
Magnetic fuse protection B2 / B4 / B6 / B10 / B16 / C2 / C4 / C6
Derating 60 ° C … 70 ° C (2.5% / K)
Output overvoltage protection (OVP) <35 V DC
Maximum capacitive load Unlimited
Active current limitation ca. 29 A
Adjustment deviation <1% (static load variation 10% ... 90%)
<2% (dynamic load variation 10% ... 90%)
<0.1% (input voltage variation ± 10%)
Residual ripple <20 mV SS
Power output 480 W
Nominal load switching peaks <10 mV SS (20 MHz)
Max. Power dissipated in no-load condition 2.2 W
Max. Power dissipated with nominal load 39 W
Response time <2 ms (U OUT (10% ... 90%))
Parallel connection yes, for redundancy and power increase
Possibility of connection in series Yes
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof)
Signal: POWER BOOST, active
Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof)
Signal: POWER BOOST, active
Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof)
Signal: POWER BOOST, active
Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Signal: DC OK, active
Description of the output U OUT > 0.9 x U N : High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current <20 mA (short-circuit proof)
Signal: POWER BOOST, active
Description of the output I OUT 19.2 V: High signal
Switchable voltage range 18 V DC … 24 V DC
Max. Inrush current ≤ 20 mA (short-circuit proof)
Signal: DC OK, potential free
Description of the output Relay
Output voltage ≤ 30 V AC / DC
Max. Inrush current ≤ 100 mA
Entrance
Connection Screw connection
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 16 mm²
Conductor cross section flexible min. 0.5 mm²
Conductor cross section flexible max. 16 mm²
Conductor cross section AWG min. 8
Conductor cross section AWG max. 6
Stripping length 10 mm
Thread M3
Min torque 1.2 Nm
Max torque 1.5 Nm
Exit
Connection Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 12
Conductor cross section AWG max. 10
Stripping length 8 mm
Thread M3
Min torque 0.5 Nm
Max torque 0.6 Nm
Signal
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Thread M3
Min torque 0.5 Nm
Max torque 0.6 Nm
Types of reporting LED
Switching output active
Relay contact
Signal output: DC OK, active
Status reporting Green “DC OK” LED
Note regarding the status indicator U OUT <0.9 x U N : LED flashing
Color green
Note regarding the status indicator Flashing LED
Signal output: POWER BOOST, active
Status reporting "BOOST" LED yellow / I OUT > I N : LED on
Color yellow
Note regarding the status indicator LED on
Signal output: U IN OK, active
Status reporting Yellow “U IN <19.2 V" LED / U IN <19.2 V DC: LED on
Color yellow
Note regarding the status indicator LED on
Signal output: DC OK, potential free
Note regarding the status indicator U OUT > 0.9 x U N : closed contact
Number of phases 1.00
Input / output insulation voltage 1.5 kV (approval)
1 kV (Testing)
Input / output insulation voltage 1 kV (approval)
Product type DC / DC Converter
MTBF (IEC 61709, SN 29500) > 554000 h (40 ° C)
Features of insulation
Protection class III
Degree of pollution 2
Length 82 mm
Height 130 mm
Depth 125 mm
Mounting dimensions
Left / right mounting distance 0 mm / 0 mm (≤ 70 ° C)
Left / right side installation distance (active) 15 mm / 15 mm (≤ 70 ° C)
Top / bottom mounting distance 50 mm / 50 mm (≤ 70 ° C)
Top / Bottom Mounting Distance (Active) 50 mm / 50 mm (≤ 70 ° C)
Alternative mounting
Length 122 mm
Height 130 mm
Depth 85 mm
Mounting type Rail mounting
Assembly instructions tileable: P N ≥50%, horizontally 5 mm, close to active components 15 mm, vertically 50 mm
tileable: P N <50%, horizontally 0 mm, vertical above 40 mm, vertical below 20 mm
Installation position Horizontal support rail NS 35, EN 60715
With protective paint No
Color aluminum
Case material Metal
Housing material Aluminum (AlMg3)
Shell version Galvanized steel sheet, chromium (VI) free
Environmental conditions
Degree of protection IP20
Ambient temperature (operation) -25 ° C ... 70 ° C (> 60 ° C derating, 2.5% / K, start-up approved at -40 ° C)
Ambient temperature (storage / transport) -40 ° C … 85 ° C
Ambient temperature (Startup type tested) -40 ° C
Air conditioning class 3K3 (according to EN 60721)
Maximum permissible air humidity (operation) ≤ 95% (at 25 ° C, no condensation)
Bumps 18 ms, 30g in each direction (according to IEC 60068-2-27)
Vibrations (operation) <15 Hz, amplitude ± 2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Railway applications EN 50121-4
Regulatory reference - Electronic equipment for use in power installations EN 50178 / VDE 0160 (PELV)
Electrical safety according to law EN 60950-1 / VDE 0805 (SELV)
Normative reference - Low voltage protection EN 60950-1 (SELV)
EN 60204 (PELV)
Safe separation according to law DIN VDE 0100-410
Homologation for the naval sector DNV GL (EMC B)
UL approvals UL / C-UL Listed UL 508
UL / C-UL Recognized UL 60950-1
UL ANSI / ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Electromagnetic compatibility Compliance with the EMC directive 2014/30 / EU
Electromagnetic Interference Requirements Noise emission EN 61000-6-3
EN 61000-6-4
Electromagnetic Interference Requirements Noise immunity EN 61000-6-1
EN 61000-6-2
Noise immunity EN 61000-6-2: 2005
Electrostatic discharges
Standards / Provisions EN 61000-4-2
Electrostatic discharges
Download contacts 8 kV (Test severity grade 4)
Download in the air 15 kV (Test severity grade 4)
Remarks Criterion A
High frequency electromagnetic fields
Standards / Provisions EN 61000-4-3
High frequency electromagnetic fields
Frequency 80 MHz ... 1 GHz
Strength of the test field 10 V / m
Frequency 1 GHz ... 2 GHz
Strength of the test field 10 V / m
Frequency 2 GHz ... 3 GHz
Strength of the test field 10 V / m
Remarks Criterion A
Fast transients (Burst)
Standards / Provisions EN 61000-4-4
Fast transients (Burst)
Entrance 2 kV (Test severity grade 3 - asymmetric)
Exit 2 kV (Test severity grade 3 - asymmetric)
Signal 2 kV (Test severity grade 4 - asymmetric)
Remarks Criterion A
Solicitation of voltage pulses (surge)
Standards / Provisions EN 61000-4-5
Entrance 1 kV (Test severity grade 2 - symmetrical)
2 kV (Test severity grade 3 - asymmetric)
Exit 1 kV (Test severity grade 2 - symmetrical)
2 kV (Test severity grade 3 - asymmetric)
Signal 1 kV (Test severity grade 2 - asymmetric)
Remarks Criterion A
Influence conducted
Standards / Provisions EN 61000-4-6
Influence conducted
I / O / S asymmetrical
Frequency 0.15 MHz ... 80 MHz
Remarks Criterion A
Voltage 10 V (Test severity grade 3)
Noise emission
Standards / Provisions EN 61000-6-3
Radio interference voltage according to EN 55011 standard EN 55011 (EN 55022) class B field of use Industry and domestic environment
Radio interference range according to EN 55011 standard EN 55011 (EN 55022) class B field of use Industry and domestic environment
Criterion A Normal status reporting within the set limits.
Criterion B Status signal temporarily compromised, corrected automatically by the device.
From: 401,00 € IVA esc.
Disponibile
I più venduti:
BOSCH REXROTH – Motor Pump Group Pk-30-M1-A-B921-01 – Based on A10VS045DR/31A, PPA12B4+PSA12N00
2.338,00 € IVA esc.
SEW EURODRIVE – WAF30-DT80K4-24 – Gear-Reducer
461,00 € IVA esc.
BOSCH REXROTH – M4SEW6D3X/420MG24N9 – Electrovalve
548,00 € IVA esc.
BOSCH REXROTH – 4WEH10E-4X – Electrovalve
305,00 € IVA esc.