Duenne non è un rivenditore autorizzato PHOENIX
2900414 – PHOENIX
Static relay for starting – ELR H5-IES-SC- 24DC / 500AC-2
2900414
Product type Three-phase static relays
Operation 100% ED
Number of phases 3
Type of static relay Reverse starter
Maximum power dissipated under nominal conditions 2.2 W
Switching frequency ≤ 2 Hz (depending on the load)
Maximum dissipated power 3.3 W
Minimum dissipated power 1.1 W
Type of assignment 1
Diet
Supply voltage of the dimensioning control circuit U S 24 V DC
Control supply voltage range 19.2 V DC … 30 V DC
Power supply, control, sizing current I S 40 mA
Protection circuit Overvoltage protection
Prot. Against polarity inversion
Features of insulation
Rated insulation voltage 500 V
Impulsive dimensioning voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the control input voltage, the control supply voltage and the auxiliary circuit to the main circuit Safe separation (IEC 60947-1 / EN 50178) with operating voltage ≤ 300 V AC
Basic insulation (IEC 60947-1) with operating voltage ≤ 300 … 500 V AC
Safe separation (EN 50178) with operating voltage 300 … 500 V AC
Insulation characteristics between the control input voltage, the control supply voltage and the auxiliary circuit Safe separation (IEC 60947-1) with auxiliary circuit ≤ 300 V AC
Safe separation (EN 50178) with auxiliary circuit ≤ 300 V AC
Check
Entrance denomination Left / right control input
Rated working voltage U C 24 V DC
Activation voltage range 19.2 V DC … 30 V DC
Rated working current I C 5 mA (Input type 1)
Switching threshold 9.6 V (“0” signal)
19.2 V (Signal “1”)
Switching level <5 V DC (for EMERGENCY STOP)
Typical switch-off time <30 ms
Protection circuit Prot. Against polarity inversion
AC output
Tens. of exercise of dimensionam. U and 500 V AC
Operating voltage range 42 V AC ... 550 V AC
Operating current I e 2.4 A (AC-51)
2.4 A (AC-53a)
Network frequency 50/60 Hz
Load current range 180 mA ... 2.4 A (see derating)
Trip curve in accordance with IEC 60947-4-2 Class 10A
Cooling time 20 min. (for Auto Reset)
Leakage current 0 mA
Protection circuit Overvoltage protection
Alarm output
Note Response message: potential-free changeover contact, signal contact
Making contacts 1 diverter contact
Breaking capacity IEC 60947-5-1 3 A (230 V, AC15)
2 A (24 V, DC13)
Control circuit
Connection Screw connection
Stripping length 8 mm
Thread M3
Rigid conductor section 0.2 mm² ... 2.5 mm²
Flexible conductor section 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lb f -in. ... 7 lb f -in.
Control circuit
Connection Screw connection
Stripping length 8 mm
Thread M3
Rigid conductor section 0.2 mm² ... 2.5 mm²
Flexible conductor section 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Length 22.5 mm
Height 107 mm
Depth 114 mm
From: 118,00 € IVA esc.
Disponibile
I più venduti:
VICKERS – DG4V 3 3C M U B6 60 – Solenoid Valve
114,00 € IVA esc.
SEW EURODRIVE – SA52 DT 80N8-2 – Gear-Reducer
815,00 € IVA esc.
RASTELLI RACCORDI – TN143-1″X1″1/2RTR – Flange
31,00 € IVA esc.
GEFRAN – 40T-96-4-24-RR-0-3-0-1 – Pressure Reducer
175,00 € IVA esc.